PLAY PODCASTS
EEVblog 1734 – Uni-T UT892 2000V High Voltage Multimeter TESTED

EEVblog 1734 – Uni-T UT892 2000V High Voltage Multimeter TESTED

The Uni-T UT892 High Voltage Multimeter is unusually rated to 2000V! Teardown and testing time, is it any good? 00:00 – Uni-T UT892 2000V High Voltage Multimeter 02:39 – Unboxing 03:40 – FAIL right off the bat! Probes matter.

EEVblog

February 17, 2026

Audio is streamed directly from the publisher (eevblog.org) as published in their RSS feed. Play Podcasts does not host this file. Rights-holders can request removal through the copyright & takedown page.

Show Notes

The Uni-T UT892 High Voltage Multimeter is unusually rated to 2000V!
Teardown and testing time, is it any good?

00:00 – Uni-T UT892 2000V High Voltage Multimeter
02:39 – Unboxing
03:40 – FAIL right off the bat! Probes matter.
05:53 – Teardown
08:06 – Where’s the MOV’s?
09:07 – The case design leaves a lot to be desired
09:23 – PCB switch contact side
09:44 – Houston, we have a clearance problem.
11:20 – It’s going in unprotected
13:08 – The case sucks
13:56 – High Voltage testing within range
15:15 – What’s up with this NCV tester?
16:48 – Do we care about the autoranging and continuity tester at this point?
17:35 – 2500V test
19:05 – 5000V test!
21:03 – Inspection + chipset
21:26 – 5000V test again with cover off
22:20 – What a surprise! It failed exactly where I said it would.
23:25 – Proper high voltage design
24:50 – Conclusion

Forum: https://www.eevblog.com/forum/blog/eevblog-1734-uni-t-ut892-2000v-high-voltage-multimeter-tested/